SPECIFICATIONS
39c Churchill Way, Lomeshaye Ind. Est, Nelson, Lancs, BB9 6RT, England
Tel 01282 695500 Fax 01282 695511 Helpline 09066 191 133*
E-mail sales@voltek.co.uk Website www.voltek.co.uk
*Helpline calls cost 60p/minute. Open 9am to 5pm, Mon to Fri.
Voltek reserves the right to change any product or specification without notice
(c) 2006 Voltek Automation Ltd. Issue 2
PIR Sensor
Operating voltage
12V dc
Alarm current consumption
12mA (LED enabled) 6mA (LED disabled)
Standby current consumption 3mA
Sensor
Dual element, thermally stabalised
Signal output
Standby - 12V through a 22K resistor
Alarm - 0V through a 100R resistor
Ambient light level sensor
20M
O
Detection
18 metres (max) over 90º (standard lens)
Lighting Controller
Operating voltage
230Vac 50/60Hz
Output
230Vac 10A (2.3KW)
Output fuse
20mm 10A td (time delay)
Low voltage output
12Vdc 100mA
Timer
3 seconds to 7 minutes (resetable type)
Night time start
adjustable from bright day light to pitch black.
Operating temperature
-10ºC to +40ºC
Weatherproofing
IP55
Dimensions
1800, 1802, 1811 - 59W x 39H x 56D mm
1803 -120W x 90H x 63D mm
1804 - 90W x 113H x 84D mm
Package weight
1800 - 0.56Kg 1802 - 0.59Kg 1803 - 0.41Kg
1804 - 0.16Kg 1811 - 0.4Kg
Package size
1800, 1802, 1811 - 77W x 163H x 165D mm
1803, 1804 - 95W x 95H x 117D mm
Approvals
CE directive 93/68/EEC
EMC directive 89/336/EEC
BS EN 50081-1 : 1992, BS EN 50082-1 : 1992
Low voltage directive (LVD) 73/23/EEC